Dimension Information (in inches)
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4” x 10”
rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used.
Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust
with the space between studs, or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of
3-1/4” x 10” rectangular or 6” diameter round duct should
not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc.,
present additional resistance to airflow and are equivalent
to a section of straight duct which is longer than their
actual physical size. When calculating the total duct length,
add the equivalent length of all transitions and adaptors plus
the length of all straight duct sections. The chart below
shows the approximate feet of equivalent length of some
typical ducts.
Listed by
Underwriters
Laboratories
Grille
Filter Kit Accessory
Filter Kit
JX81D–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
cannot be vented
to the outside.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Round Elbow 10 Ft.
D. 45° Round Elbow 5 Ft.
E. 90° Rectangular Elbow 25 Ft.
F. 45° Rectangular Elbow 5 Ft.
G. Roof Cap 24 Ft.
Specification Revised 7/13